Airworthiness Directives
|
Header
Information
DEPARTMENT OF TRANSPORTATION
Federal Aviation Administration
14 CFR Part 39
AD 47-30-07
Airworthiness Directives; Beech Model AT-11
Aircraft
Preamble
Information
Regulatory
Information
47-30-07 BEECH: (Was Mandatory Note 3 of AD-2-582-2.) Applies Only to
AT-11 Aircraft Which Are Not Equipped With
Generator Circuit Protective Devices.
To be accomplished prior to certification or, if certificated, on next periodic
inspection but not later than October 1, 1947.
In accordance with Figure 1 install a 50-ampere trip-free circuit breaker,
Spencer Thermostat Co. PLM-50 or equivalent, between the battery terminal of
each generator cutout and its respective ammeter shunt. The circuit breakers
should be accessible in flight and labeled respectively: "LEFT GEN. CIRCUIT" and
"RIGHT GEN. CIRCUIT."